Percentage Solution Calculator
Calculate the concentration of a percentage solution (% w/v, % w/w, or % v/v), or work out how much solute you need to prepare a solution at a target percentage — for reagent, stain, and media preparation.
Solution details
Concentration
–
Common Lab Percentage Solutions (tap to load)
Normal Saline
0.9% w/v
Isotonic diluent, wet mounts
Neutral Buffered Formalin
10% w/v
Tissue fixation
Ethanol / Isopropanol
70% v/v
Disinfection, dehydration
Hydrogen Peroxide
3% v/v
Disinfectant, catalase test
Potassium Hydroxide
20% w/v
Fungal skin/nail wet mount
Crystal Violet
1% w/v
Gram stain reagent
Formulas
% w/v = (Weight of solute in g ÷ Volume of solution in mL) × 100
% w/w = (Weight of solute in g ÷ Weight of solution in g) × 100
% v/v = (Volume of solute in mL ÷ Volume of solution in mL) × 100
About percentage solutions
A percentage solution expresses how much solute is present per 100 parts of the total solution. Laboratories use three conventions depending on the physical states involved: % w/v for a solid dissolved in a liquid (the most common form for reagents and stains), % w/w for two solids or a solid in a semi-solid, and % v/v for a liquid diluted in another liquid. The unit is always parts per 100, but what "part" means (grams or mL) changes with the convention — which is why matching the right type to your reagent matters.
Preparing a solution from a target percentage
- For % w/v: weigh the solute, dissolve it in less than the final volume of solvent, then add solvent up to the total final volume — do not simply add the solute to the full final volume of solvent, as the solute itself displaces some volume.
- For % w/w: weigh the solute and the diluent separately so their combined weight equals the target total weight.
- For % v/v: measure the solute volume, then add diluent up to the final total volume using a volumetric flask or cylinder.
Notes and limitations
- This calculator assumes ideal mixing with no significant volume contraction or expansion; for precise reagent work, always follow your lab's validated SOP.
- For serial dilutions from a stock solution (C₁V₁ = C₂V₂), use a dedicated dilution calculator — this tool is for preparing a solution from pure solute, not diluting an existing stock.
- Always label prepared reagents with concentration, preparation date, and expiry per your quality management system (e.g. ISO 15189).